KNOWLEDGE
Knowledge
Producer goods
【We Also Want to Visualize the Operating Status of Older Equipment】How to Acquire Operating Status from Equipment Without Built-in Sensors
2026-11-20
Many production machines that have been in use for many years are not equipped with sensors for checking operating status or mechanisms for sending data externally. As a result, many factories still rely on workers to make periodic rounds and check whether equipment is running, stopped, or in a particular operating state.
Even when there is a need to visualize the operating status of such equipment, replacing the entire machine with new equipment can be costly. It may also be difficult to determine what kind of data can be acquired from older equipment and what should be measured in order to understand its operating status.
This article explains how to retrofit sensors to existing equipment to acquire data, how to select measurement items according to the operating status you want to monitor, and the difference between data visualization and failure prediction.
Table of Contents
- Why is it difficult to check the operating status of older equipment?
- How to retrofit sensors without replacing equipment
- What should be measured to check equipment operating status?
- What is the difference between data visualization and failure prediction?
- FAQ
- Key terms for understanding this article
Why is it difficult to check the operating status of older equipment?
In factory production environments, it is desirable to identify equipment stoppages as quickly as possible in order to keep line downtime as short as possible. If possible, it is also useful to detect signs that may lead to a stoppage in advance.
However, many production machines that have been used for many years are not equipped with functions for outputting running or stopped status externally, or with mechanisms for recording operating history. With such equipment, even if the machine itself is operating, it can be difficult to check later when it stopped or how long it remained stopped.
At sites like these, workers often make rounds, visually check indicator lights and meters, and record the operating status. However, periodic checks make it difficult to identify short stoppages or changes in status that occur between inspections. It is also not easy to monitor the operating status of multiple production lines collectively.
For this reason, a mechanism is needed that can continuously acquire and manage equipment operating status as data without relying only on visual checks by workers.
How to retrofit sensors without replacing equipment
Even if existing equipment does not have a data collection function, it may still be possible to determine its operating status by using signals output from the equipment or by adding sensors.
With BraveJIG, sensor modules can be retrofitted according to the existing equipment, and the acquired data can be collected wirelessly.
The first point to check is whether there are any usable signals available from the equipment.
For example, signals output from a control panel can provide clues for determining the operating status of the equipment. Voltage or current values can also be acquired to assess equipment operation. If a signal tower is installed, its illumination status can be detected with a sensor. If analog sensors are already installed, their values can also be acquired using compatible BraveJIG modules.
For equipment from which such signals cannot be extracted, additional sensors that measure acceleration or distance can be installed to obtain information such as machine movement or product passage.
The appropriate method differs depending on the structure and application of the equipment, so it is necessary to consider whether to use existing signals or add new sensors.
The acquired data is transmitted to a BraveJIG router via Bluetooth and can be displayed and stored using the visualization application “BraveJIG PLUG.” This makes it possible to continuously monitor changes in equipment status, rather than checking only when workers make their rounds, and to use the data to understand operating conditions.
What should be measured to check equipment operating status?
To understand the operating status of equipment, the first step is to clarify what you want to monitor.
For example, the data required to determine whether a machine is running is different from the data needed to monitor temperature changes during processing or production quantity.
BraveJIG offers the following types of sensor modules depending on what is being measured.
Measurement Item | Example Information That Can Be Checked | Example Compatible Module |
Voltage | Changes in voltage output from control panels or existing sensors | 2ch ADC Module |
Current | Measurement values obtained from analog sensors with 4-20mA output | 2ch 4-20mA Module |
Contact signal | ON/OFF status of switches or the status of control devices | 2ch Dry Contact Input Module / 2ch Wet Contact Input Module |
Movement / stationary state | Operating state of machines or equipment | Acceleration Module |
Indicator light status | Display status such as that of signal towers | Illuminance Module |
Temperature | Temperature changes in processing areas or equipment | Thermocouple Module |
Production quantity | Product passage or production count | Toru, or a combination of an external sensor and a Contact Input Module |
The appropriate measurement method differs depending on the equipment
For example, if a control panel outputs a contact signal corresponding to running and stopped states, the status can be acquired using a Contact Input Module.
On the other hand, if acceleration changes according to equipment movement, an Acceleration Module can be used to distinguish between moving and stationary states.
If production quantity needs to be checked, Toru can be used to detect product passage, or signals from devices such as photoelectric sensors can be acquired using a Contact Input Module.
In this way, even when the objective is the same—“visualizing equipment operating status”—the appropriate measurement method differs depending on the equipment structure and operating conditions.
In addition, it is not always possible to determine the actual operating status correctly from the acquired signal alone. For example, if equipment is powered on but not producing anything, the presence or absence of voltage alone may not be sufficient to determine whether it is actually operating.
Therefore, when selecting sensors, it is important to check the relationship between the information you want to obtain and the measurement data being collected.
What is the difference between data visualization and failure prediction?
Once equipment status can be acquired as data, the information can be considered not only for checking operating status, but also for early detection of abnormalities and failure prediction.
However, data visualization and failure prediction are not the same thing.
Visualization means displaying and recording values acquired from equipment, such as voltage, temperature, and movement status, so that the current condition and past changes can be reviewed.
Failure prediction, on the other hand, involves detecting changes in accumulated data that differ from normal conditions and determining whether there are signs that may lead to equipment failure.
For example, even if equipment temperature is rising, the measurement value alone does not indicate whether the change is part of normal operation or a sign of an abnormality. It is necessary to compare the value with operating conditions, historical data, and the equipment’s normal state.
The type of data that should be monitored as a sign of abnormality also varies by equipment type. For some equipment, temperature changes may be important, while for others it may be more appropriate to monitor changes in current values or operating state.
BraveJIG can be used to acquire and accumulate the status data needed for this type of analysis. However, simply collecting data does not automatically enable failure prediction.
When aiming for failure prediction, it is necessary to select measurement items suitable for the equipment and consider the criteria and analytical methods used to determine whether a condition is abnormal.
If you are unsure what kind of data should be acquired or which sensor module is suitable for your existing equipment, please contact us using the form below.
FAQ
Q1: Can the operating status of older equipment without sensors still be monitored?
A1: In some cases, data related to operating status can be acquired by retrofitting sensors to existing equipment. BraveJIG offers modules that can be selected according to the information to be monitored, such as control panel signals, indicator light status, and equipment movement.
Q2: Is it necessary to replace the equipment with a new machine?
A2: It is not always necessary to replace the entire machine. Data collection can be started by acquiring usable signals from existing equipment or by adding external sensors while continuing to use the current equipment.
Q3: Which sensor module should be selected?
A3: The appropriate module depends on the information to be monitored, such as running/stopped status, temperature, or production quantity. The first step is to clarify the monitoring objective and then select a module according to the signals available from the equipment and the measurement environment.
Q4: Can BraveJIG be used for failure prediction?
A4: BraveJIG can acquire and visualize equipment status data, but this alone does not mean that failures can be predicted. Failure prediction requires understanding the normal operating state and signs of abnormalities for each piece of equipment, as well as setting appropriate analysis methods and judgment criteria.
Key Terms for Understanding This Article
- Retrofit: Adding equipment such as sensors to existing machinery without replacing the machinery itself.
- 2ch ADC Module: A module used to acquire voltage values from devices such as industrial sensors with voltage output and convert them into digital data.
- Contact Signal: A signal that indicates the state of a device, such as the ON/OFF status of a switch or control device.
- Visualization: Displaying acquired data as numerical values or graphs so that equipment status and changes can be checked.
- Failure Prediction: Analyzing equipment status data to detect signs of abnormalities that may lead to failure in advance.
Company Information
IoT Sensor Modules for Factories / LAN and USB Routers for IoT Data Collection / IoT Data Visualization Software
We are Braveridge, an IoT device manufacturer from Fukuoka. Leveraging our strength in wireless communication technology, we have built a strong track record in developing and mass-producing numerous ...
CONTACT
Contact