Producer goods

【Start with the Smallest Possible Setup】How to Visualize Equipment Operating Status with a Single PC and Expand to Full Operation

2026-11-20

【Start with the Smallest Possible Setup】How to Visualize Equipment Operating Status with a Single PC and Expand to Full Operation

When considering the introduction of IoT in a factory, internal information security rules may not allow devices that have not yet been sufficiently verified to connect to the company LAN.

In addition, if the system configuration used during testing differs significantly from the one used in actual operation, equipment may need to be replaced or reconfigured, increasing the burden of implementation.

So how can equipment data acquisition be tested without using the internal LAN, while still making use of the same configuration in actual operation? This article explains how to start IoT verification with a single PC while keeping future factory-wide deployment in mind.

Table of Contents

  • Why factories may want to test IoT without connecting to the internal LAN
  • How to visualize equipment operating status with a single PC
  • How to transition to actual operation using the same sensors from the verification stage
  • How to select a router according to factory scale
  • FAQ
  • Key terms for understanding this article

Why factories may want to test IoT without connecting to the internal LAN

When introducing new IoT devices into a factory, security checks or connection approval from the information systems department may be required.

In particular, devices whose performance or safety has not yet been verified may be restricted from connecting to the internal network. As a result, even if the production department wants to collect equipment data, it may not be possible to begin testing immediately.

In addition, even if data can be collected during a PoC, the same system configuration used for testing cannot always be used directly in actual operation. For example, a small computer such as a Raspberry Pi may be used to acquire data during a PoC. However, on an actual production line, there may be locations where a power supply cannot be secured. In environments where dust or water droplets are present, it may also be difficult to install equipment with an exposed circuit board as-is.

If sensors, peripheral devices, and even the network configuration have to be selected again from scratch, more time and effort may be required than during the PoC itself.

To avoid this burden, it is important not only to choose a configuration that can be tested without connecting to the internal LAN, but also one that allows the equipment used during verification to continue being used in actual operation.

How to visualize equipment operating status with a single PC

With BraveJIG, equipment data can be collected without using the internal LAN or the internet by combining sensor modules with a USB router.

The basic data flow is as follows.

bravejig-product-diagram_144500b7-cadc-4d17-bf67-4ae74fe251af.png

A sensor module installed on the equipment acquires measurement data and sends it wirelessly to the USB router via Bluetooth. The USB router can be connected directly to a PC via USB-C, allowing the data to be imported without going through the internal network.

Another feature is that no communication cable needs to be installed between the sensor module and the router, which can reduce the burden of wiring work inside the factory.

As a general guideline, Bluetooth communication distance is approximately 50–200 meters in actual operating environments, and up to approximately 500 meters in open areas with favorable communication conditions. This makes it possible to collect data from equipment located at a distance. However, the communication range will vary depending on equipment layout and the surrounding radio environment.

BraveJIG also offers devices that support battery operation as well as dustproof and waterproof specifications. This allows a configuration to be selected according to the installation environment, including locations where securing a power supply is difficult or factories where dust or water droplets are present.

In this way, sensors can be retrofitted to existing equipment or production lines, allowing IoT verification to begin without large-scale wiring work.

Data acquired from the equipment can be checked on a PC

KL 2.1_93f23d65-f6d7-4823-b908-55244774ba49.png

Data acquired from the sensor modules can be checked using “BraveJIG PLUG,” a visualization application provided free of charge by BraveJIG.

BraveJIG PLUG is an application that runs on Windows PCs. In addition to acquiring and storing sensor data, it also supports displaying the data as graphs in a web browser.

Measurement values can be checked in real time, and historical data can also be reviewed. This makes it possible to verify whether the acquired data is useful for understanding equipment conditions without having to develop a dedicated display system from scratch.

BraveJIG PLUG also provides an API for linking data with existing systems, allowing verification results to be used in proprietary applications as well.

BraveJIG uses a one-time purchase model for the required equipment, allowing implementation to begin with a small-scale configuration while keeping initial costs down. Configurations using a USB router or LAN router do not require a SIM card or cloud service, so there are no associated monthly fees.

How to transition to actual operation using the same sensors from the verification stage

Once the PoC confirms that the required data can be acquired, the next step is to consider operation in the actual factory environment.

With BraveJIG, the sensor modules used during verification can continue to be used while changing from a USB router to a LAN router, allowing the system to transition to a configuration that uses the internal LAN.

bravejig-lan-diagram_bd850e05-7fb6-4824-b1d5-ed00e24f464c.png

The sensor modules and communication method remain the same between the verification stage and actual operation. The main changes are the router that receives the data and the communication path beyond it.

BraveJIG PLUG supports both USB routers and LAN routers. By configuring the application according to the router being used, the same application can continue to be used for data collection and visualization.

When transitioning to actual operation, the router installation location, communication environment, and internal LAN settings need to be checked. However, because the equipment and software used during verification can be retained, it is possible to move to the production environment without rebuilding the entire system from scratch.

How to select a router according to factory scale

BraveJIG offers routers that can be selected according to the scale of use and the network environment.

Because the USB router connects directly to a PC, it is suitable for PoCs involving specific equipment or a limited area.

On the other hand, when collecting equipment data over a wider area, such as an entire factory or multiple floors, a LAN router connected to the internal LAN can be used.

BraveJIG’s “LAN Router Type2” supports fixed IP addresses and can be used in medium- to large-scale network environments.

Comparison Item

USB Router

LAN Router Type2

Main use

PoC or small-scale trial

Medium- to large-scale operation

Connection to PC

Direct connection via USB-C

Connection through the internal LAN

Internal LAN

Not required

Required

Typical use

Acquiring and checking data from specific equipment

Collecting data from multiple machines or areas

By placing LAN routers in multiple areas within the factory, it is also possible to consider a configuration in which equipment data from each area is brought into the internal network.

However, the required number of routers and their installation locations will vary depending on equipment placement, the number of sensors, and the communication environment.

If you are unsure about questions such as “What kind of configuration is suitable for our factory?” or “How should we expand the operational scope after verification?”, please feel free to contact us using the form below.

FAQ

Q1: Can we start a PoC even if the IT department has not yet approved connection to the internal LAN?
A1: By using BraveJIG’s USB router, sensor data can be imported directly into a PC without going through the internal LAN or the internet. However, the use of equipment for verification must still comply with the company’s internal security rules.

Q2: Can data acquired with the USB router be displayed on a PC?
A2: By using BraveJIG PLUG, acquired data can be stored and displayed as graphs in a web browser. Measurement values can also be checked in real time, and historical data can be reviewed.

Q3: Do the sensor modules need to be replaced after the PoC is completed?
A3: The sensor modules used during verification can continue to be used after switching to a LAN router. However, connection settings for the router or adjustments according to the installation environment may be required.

Q4: How should USB routers and LAN routers be used differently?
A4: Because the USB router connects directly to a PC, it is suitable for PoCs in a limited area or small-scale operation. The LAN Router Type2, on the other hand, supports connection to the internal LAN and can be used for data collection over a relatively wide area, such as an entire factory or multiple floors.

Key terms for understanding this article

  • PoC: A small-scale test conducted before full implementation to verify whether a technology or system functions as intended.
  • USB Router: A device that receives data from sensor modules via Bluetooth communication and transfers it to a PC through a USB connection.
  • LAN Router: A device that transfers data received from sensor modules into the internal LAN.
  • Sensor Module: A device used to acquire measurement data such as temperature or voltage according to the target application. BraveJIG offers multiple types for different uses.
  • API: A mechanism that allows data or functions to be linked between different software applications or systems.

Company Information

Braveridge Co., Ltd.

Main 3 Products

IoT Sensor Modules for Factories / LAN and USB Routers for IoT Data Collection / IoT Data Visualization Software

Homepage URL

Display URL

We are Braveridge, an IoT device manufacturer from Fukuoka. Leveraging our strength in wireless communication technology, we have built a strong track record in developing and mass-producing numerous ...

CONTACT

Contact

This is the inquiry form for Braveridge Co., Ltd.. Please enter your inquiry details.

This service is intended for consulting on processing projects and requesting quotes.
Please do not use it for company PR or sales activities.
If we receive complaints about the content sent, we may take measures such as forcibly suspending usage.