DTY-ELK01F Blow-Type Ionizer / Operating Pressure of 0.01–0.3 MPa / Ideal for Precision Spot Blowing on Small Workpieces
KOGANEI (THAILAND) CO., LTD. introduces the DTY-ELK01F Blow-Type Ionizer — Small Flow, designed to eliminate static electricity from small workpieces that require precise treatment. It helps reduce the risk of workpieces moving due to excessive airflow and is ideal for precision spot-blowing applications in manufacturing processes.
The DTY-ELK01F is designed to operate with a low air flow rate, making it suitable for small, lightweight workpieces or applications where the workpiece position must be carefully controlled. Its compact body also allows for easy installation in confined spaces.
Table of Contents
- Key Features of the DTY-ELK01F Blow-Type Ionizer
- Suitable for Environments Requiring a High Level of Cleanliness
- Technical Specifications and Performance
- Operating Status Monitoring via LED Indicators
- Frequently Asked Questions (FAQ)
Key Features of the DTY-ELK01F Blow-Type Ionizer
The DTY-ELK01F is suitable for eliminating static electricity from small workpieces, particularly in applications that require precise air blowing without excessive airflow that could cause the workpiece to move.
- Low air flow suitable for small workpieces
It helps eliminate static electricity while reducing the risk of lightweight workpieces moving or being blown away by the airflow. - Stable static elimination performance
The unit uses a high-frequency AC system to generate ions continuously and consistently, making it suitable for manufacturing processes that require precise operation. - Compact body for easy installation
The unit’s volume has been reduced by 40% compared with the previous model, providing greater installation flexibility in confined spaces. It can also be mounted directly using the mounting holes on the body.
Suitable for Environments Requiring a High Level of Cleanliness
For manufacturing processes where airborne particles or contaminants must be controlled, the DTY-ELK01F-L Low Particle Generation Type is available. This model limits particle generation to 50 particles or fewer.
It is therefore suitable for applications that require a high level of cleanliness and reduced risk of particle contamination during manufacturing processes.
※ For more details, please download the PDF attached to this article or complete the inquiry form below.
Technical Specifications and Performance
The table below shows the basic specifications for selecting the DTY-ELK01F.
Item | Specification |
Ion balance | Within ±10 V, using the standard nozzle at 0.3 MPa and a distance of 50 mm |
Ozone generation | 0.015 ppm or less, using the standard nozzle at 0.3 MPa and a distance of 300 mm |
Operating pressure | 0.01 to 0.3 MPa |
Input voltage | 24 VDC ±5% |
Current consumption | Approximately 50 mA |
Static elimination method | High-frequency AC, approximately 2 kVp-p |
Operating Status Monitoring via LED Indicators
The DTY-ELK01F is equipped with LED indicators that allow users to check the operating status of the unit directly from the main body.
- Green PWR LED
Indicates that power is being supplied to the system. - Blue H.V LED
Indicates that the system is generating a high-voltage discharge. - Yellow CHK LED
Indicates an abnormality in the discharge operation. The H.V LED automatically turns off when this condition is detected. - Red ALM LED
Indicates that a system abnormality has been detected. The H.V LED turns off when an alarm occurs.
Frequently Asked Questions (FAQ)
Q: Can the DTY-ELK01F be used at an air pressure above 0.3 MPa?
A: The unit should be operated within the specified pressure range of 0.01 to 0.3 MPa to maintain its performance and service life.
Q: What types of workpieces is the DTY-ELK01F suitable for?
A: It is suitable for small or lightweight workpieces that require localized static elimination without excessive airflow that could cause them to move.
Q: What should I do if the yellow CHK LED turns on?
A: Check for abnormalities in the discharge operation, including the sequence in which air and electrical power are supplied. The discharge needle assembly should also be inspected and cleaned if dust has accumulated, helping maintain stable operation.
Interested in the DTY-ELK01F Blow-Type Ionizer?
For applications that require static elimination on small workpieces, reduced workpiece movement caused by airflow, and greater precision in spot-blowing operations, please download the PDF attached to this article or complete the inquiry form below to request more information from KOGANEI (THAILAND) CO., LTD.
Company Information
pneumatic equipment / electric-operated devices / electrostatic elimination equipment
KOGANEI (THAILAND) CO., LTD. operates in Thailand under KOGANEI Corporation, Japan, providing Pneumatic and Integrated Automation Solutions for industrial applications. Established in Thailand in 2006 ...
CONTACT
Contact